The JUER Electric® Wholesale DC 1000v Surge Protective Device made in China is suitable for the new energy wind power generation system,its working voltage covers 500V,800V and 1000V.It is installed in the main power system at DC circuit,to protect against the indirect lighting current,direct lighting current or other instantaneous over voltage.
a.Module design, convenient installation,with easy electric maintains operation
b.Built-in over current and over heat, temperature control open circuit technology
c.Adopt independent intelligence property right and high performance sensitivity resistance plates
d.Small creepage current,fast response time, remnant low voltage
e.With remote connection, can realize remote control
solar surge protector | ZC-PV600 | MR-PV1000 | ||||
PV DC specific (IEC 6614-1/EN 61643-11) | ||||||
Pole | 2 pole | 3 pole | ||||
Electrical Parameter | ||||||
Classifical test | II | II | ||||
Uoc max (V DC) | 550 | 600 | 800 | 1000 | ||
Uc (V DC) | 550 | 600 | 1000 | 1000 | ||
In(8/20)us (KA) | 20 | 20 | ||||
Imax(8/20)us (KA) | 40 | 40 | ||||
Up (KV) | 2 | 3.8 | ||||
Remote control and indication | ||||||
Indication window | ||||||
Plug-in module | ||||||
Remote signal contact | ||||||
Remote signal contact | Max working volt | 250V AC/30V DC | 250V AC/30V DC | |||
Max working amp 1A (250V/AC) | 1A (250V/AC) | 1A (250V/AC) | ||||
1A (30V DC) | 1A (30V DC) | 1A (30V DC) | ||||
Wiring & installation | ||||||
Wiring capacity(mm2) | Hard wire | 4-25mm | 4-25mm | |||
Flexible wire | 4-16mm | 4-16mm | ||||
Stripping length | 10 | 10 | ||||
Terminal screwa | M5 | M5 | ||||
Torque(Nm) | Main ciruit | 3.5 | 3.5 | |||
Remote signal contact | 0.25 | 0.25 | ||||
Protection class | All profile | IP40 | IP40 | |||
Connection port | IP20 | IP20 | ||||
Installation environment | No obvious shock and vibration | |||||
Altitude(m) | ≤ 2000 | ≤ 2000 | ||||
Working temperature | 67 | 67 | ||||
Relative humidity | 30%-90% | 30%-90% | ||||
How to install | Install with H35-7.5/DIN35 stell mounting rail | |||||
Size(mm) (W*H*L) | W | 36 | 54 | |||
H | 90 | 90 | ||||
L | 48.5 | 48.5 | ||||
Weight (KG) | 0.28 | 0.42 | ||||
Nominal PV system volt | 600V | 1000V | 1200V | |||
MCOV(UCPV) | 700V DC | 1170V DC | 1200V DC | |||
Max system discharge Current (8/20us) (Imax) | 40KA | 40KA | 30KA | |||
Volt protection leve (UP) | ≤ 2.5KV | ≤ 4.0KV | ≤ 4.5KV | |||
Volt protection Level at 5KA (UP) | ≤ 2.0KV | ≤ 3.5KV | ≤ 4.0KV | |||
Integrate fuse breaking capacity/interrupting rating | 30KA/1000V DC | 30KA/1000V DC | 30KA/1200V DC | |||
Technology | Short-circuit interruption (SCI) overcurrent protection | |||||
Operating temperature range | -40 to +80 | |||||
Nominal discharge current | 12.5KA | |||||
Response time (ta) | <25ns | |||||
Operating state/fault indication | Green (good) / Red (replace) | |||||
Mounting | 35mm DIN Rail per EN 60715 | |||||
Degree protection | IP20 | |||||
capacity | 3 modules DIN 43880 |